Extreme Networks Network Card WM200 User Manual

Summit WM200/2000 Controller Installation Instructions  
Getting started  
Step 2 – Connect to a power supply  
Configure Management interface  
Configure your system  
These instructions provide installation technicians with a high-  
8
Type the following information:  
5 – Install the controller license:  
®
level overview for installing the Summit WM200/2000  
Hostname – The name of the controller  
Domain – The IP domain name of the enterprise network  
Management IP Address – The new IP address for the  
controller’s Management port. Change this as appropriate  
for the enterprise network.  
Install the license and confirm the latest firmware version is  
loaded.  
Controller.  
Unpack the controller:  
6 – Configure the WM-AD:  
1
2
3
Lift the controller, in its protective foam casing, straight up  
and out of the carton.  
Lay the controller on a flat surface and slide off the foam  
casing.  
Confirm that your carton contains all of the appropriate  
content.  
Research and configure the traffic topologies the network will  
support.  
Subnet mask – The appropriate subnet mask for the IP  
address to separate the network portion from the host  
portion of the address (typically 255.255.255.0)  
7 – Install, register, and assign APs to the WM-AD:  
Connect the two power cords to the controller.  
Confirm the latest firmware version is loaded.  
Management Gateway – The default gateway of the  
Deploy APs to their corresponding network locations. If  
applicable, configure a default AP template for common radio  
and WM-AD assignment.  
network  
Carton contents:  
NOTE  
Primary DNS – The primary DNS server used by the  
network  
Secondary DNS – The secondary DNS server used by the  
network  
One controller  
Two mounting brackets  
Eight M3x6 lens head machine screws  
Four self-adhesive rubber feet  
One crossover RJ45 Ethernet cable (for installation)  
For information on installing and powering the wireless APs,  
see the Altitude AP Installation Instructions.  
If only one power cord is connected, the disconnected power supply LED  
is illuminated red.  
Power off the controller:  
9
To save your changes and disconnect the Web connection  
between the laptop and the controller, click Ok.  
The IP addresses are now set to the network you defined.  
If necessary, to power off the controller first use the  
Command Line Interface (CLI) commands or the Summit WM  
Graphical User Interface (GUI). This operation halts the  
operation of the controller software.  
Safety Information  
WARNING!  
Summit WM200/2000 Controller Installation Instructions (English  
and German)  
10 Disconnect your laptop from the controller Management port.  
11 Connect the controller Management port to the enterprise  
Summit WM User Guide (CD)  
Summit WM Getting Started Guide  
Ethernet LAN. The controller resets automatically.  
To complete powering off the controller, a manual power reset on  
the controller box is required to cycle the hardware.  
12 Log on to the Summit WM GUI. The system is visible to the  
Warnings identify information that is essential. Ignoring a warning can  
adversely affect the operation of your equipment or software.  
enterprise network.  
®
Only authorized Extreme Networks service personnel are  
permitted to service the system.  
Step 3 – Configure Management interface  
Step 4 – Configure your system  
Step 1 – Mount  
This step is optional. You can retain the default IP address of the  
controller Management port if you do not intend on connecting  
the controller to your enterprise network.  
The controller is shipped with a hardware serial shunt  
between its two cards. For technical support reasons, this  
shunt should not be removed.  
Ensure that your system is grounded according to your  
country’s electrical grounding code requirements.  
Use only original accessories or components approved for the  
system. Failure to observe these instructions may damage the  
equipment or even violate safety and EMC regulations.  
This device must not be connected to a LAN segment with  
outdoor wiring.  
To avoid electrical shock, disconnect all power supply cords  
before servicing. In the case of unit failure of one of the  
power supply modules, the module can be replaced without  
interruption of power to the controller. However, this  
procedure must be carried out with caution. Wear gloves to  
avoid contact with the module, which will be extremely hot.  
Disconnect all power before working near power supplies  
unless otherwise instructed by a maintenance procedure.  
Do not power off the controller using the power button.  
Instead, to power off the controller use the Command Line  
Interface (CLI) commands or the Summit WM GUI.  
Exercise caution when servicing hot swappable controller  
components: power supplies or fans. Rotating fans can cause  
serious personal injury.  
Check the nominal voltage set for the equipment (operating  
instructions and type plate). High voltages capable of causing  
shock are used in this equipment. Exercise caution when  
measuring high voltages and when servicing cards, panels,  
and boards while the system is powered on.  
To protect electrostatic sensitive devices, wear a wristband  
before carrying out any work on hardware.  
For system regulatory information, see the Summit WM User  
Guide (CD).  
These seven steps provide a high-level overview for configuring  
your system. For more detailed information on each  
configuration step, see the Summit WM User Guide (CD).  
Before you connect the controller to the enterprise network,  
change the IP address of the controller Management port from its  
factory defaults to the IP address suitable for the enterprise  
network. To access the controller, use a laptop computer with a  
browser. Connect the crossover Ethernet cable between the laptop  
and Management Ethernet port of the controller. Follow the steps  
below.  
1 – Before you begin configuration:  
Research the type of WLAN deployment that is required. For  
example, SSIDs, security requirements, and filter policies.  
2 – Prepare the network:  
Ensure relevant DHCP servers and RADIUS servers (if  
applicable) are available and configured.  
3 – Configure the physical port IP:  
Enable the interface. To manage the controller though the  
interface, enable Allow management.  
Mounting holes  
Configure the default IP address to be the relevant subnet  
point of attachment to the existing network, and setup the  
routing protocol and table. The default IP address is  
10.0.#.1.  
Management Port  
Console Port  
WARNING!  
NOTE  
Do not obstruct the ventilation grills of the controller.  
To configure a physical port to attach to a VLAN, define  
the VLAN as part of the IP address assignment.  
To use the flash memory card capabilities of the controller, remove the  
cover of the flash memory card from the controller and then insert a flash  
memory card. Always wear an ESD wristband when inserting or removing a  
flash memory card. A flash memory card is not shipped with your  
controller.  
Two mounting options are available, rack and table.  
Rack mounting:  
1
Attach the mounting brackets to the controller mounting  
holes.  
1
2
Statically assign an unused IP address in the 192.168.10.0/24  
subnet for the Ethernet port of the laptop.  
Launch your Web browser, and in the browser address bar,  
type https://192.168.10.1:5825. This launches the Summit  
WM GUI. The logon screen appears.  
Data Ports  
2
Attach the brackets to the rack.  
4 – Select the country and time zone:  
Table mounting:  
Log on to the Summit WM GUI and select the country and time  
zone, and then restart the controller.  
3
Ensure at least 2 inches of clearance on all sides of the  
controller for proper ventilation.  
Glue the four rubber feet to the stamped positions on the  
bottom of the controller.  
3
In the User Name box, type admin, and in the Password box,  
type abc123.  
NOTE  
4
5
6
7
Click Login.  
The controller’s clock settings are lost if the controller is powered down  
for more than 72 hours.  
From the main menu, click WM-AD Configuration.  
In the left pane, click IP Addresses.  
In the Management Port Settings section, click Modify.  
© 2007-2008 Extreme Networks, Inc. All rights reserved.  
Part number: 120389-00 Rev 02  
 

Echo Beverage Dispenser CS 330T User Manual
Exmark Lawn Mower TT20KCC User Manual
FEIN Power Tools Welder AStlxe 638 User Manual
FieldServer Server FS B OPC 01 User Manual
Frymaster Fryer Y KSCF C HC18G User Manual
Fujitsu Switch Ethernet 24 User Manual
Furman Sound Power Supply SPR 20 User Manual
Gamber Johnson Laptop Docking Station 7160 0049 User Manual
GE Convection Oven JTP75SP User Manual
Gigabyte Computer Hardware GA P31 ES3G User Manual